Knowledge Base

Frequently Asked Questions

265 answers across our full product range. Find specs, MOQ, OEM, certifications, lead times and material details for PVC, layflat, rubber, hydraulic hoses, camlock couplings and hose clamps.

PVC Hoses

Agricultural Irrigation Hose | PVC & Layflat Hose Supplier

Which irrigation hose series should I select?

This page introduces several hose families, including layflat discharge and reinforced suction hoses. Select the family for the pumping arrangement, then use its individual model table for size, pressure and length. The overview and reference examples are not one interchangeable product specification.

What working pressure should I use?

Specify pump pressure, surge conditions, suction duty if any, fluid and temperature. Working pressure, vacuum capability and temperature must come from the chosen hose model; no shared pressure range or short-term temperature allowance is confirmed for all irrigation hoses.

Is this bulk hose or a finished assembly?

The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

Is a fixed outdoor service life guaranteed?

No fixed service life is specified here. Exposure, abrasion, pressure cycles, handling and storage affect replacement needs. If a UV-resistance or durability target is required, include the test method and acceptance criteria in the enquiry for confirmation.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (by product). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Clear PVC Hose

What construction does this series use?

This is flexible transparent PVC tubing without textile reinforcement. Its pressure values belong to this unreinforced series; use the separate reinforced-hose specifications when reinforcement is required.

Which sizes belong to the listed series?

The listed models cover 3/16" – 2" (5 – 50 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 1 – 2 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

The published range for the standard construction is -5°C – +60°C. Confirm continuous operation with the actual fluid, pressure and duty cycle. No separate short-term peak rating is documented for this series; higher-temperature operation requires a separately confirmed specification.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 40, 50, 100 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Provide the medium, concentration, temperature and operating pressure. Confirm compatibility for the selected compound and fittings. Food-contact, drinking-water or other regulated uses require documents covering the actual model and intended use; they are not included merely because the hose is PVC, rubber or TPU.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Clear Reinforced PVC Hose

What construction does this series use?

The construction described on this page has a PVC inner tube, synthetic textile reinforcement and a PVC cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 13/64" – 3" (5 – 76 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 3 – 12 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

The published range for the standard construction is -5°C – +60°C. Confirm continuous operation with the actual fluid, pressure and duty cycle. No separate short-term peak rating is documented for this series; higher-temperature operation requires a separately confirmed specification.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 20, 30, 40, 50, 100 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Provide the medium, concentration, temperature and operating pressure. Confirm compatibility for the selected compound and fittings. Food-contact, drinking-water or other regulated uses require documents covering the actual model and intended use; they are not included merely because the hose is PVC, rubber or TPU.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Flexible Pool & Spa Hose

What construction does this series use?

The construction described on this page has a PVC inner tube, a rigid PVC helix reinforcement and a PVC cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 3/4" – 2". Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification. These are nominal connection sizes, not measured inner diameters.

What working pressure should I use?

The working pressures listed for this series are 4 – 6 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 50, 100 ft. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Provide the medium, concentration, temperature and operating pressure. Confirm compatibility for the selected compound and fittings. Food-contact, drinking-water or other regulated uses require documents covering the actual model and intended use; they are not included merely because the hose is PVC, rubber or TPU.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Heavy Duty PVC Fabric Reinforced Suction Hose Corrugated

What construction does this series use?

The construction described on this page has a PVC inner tube, polyester braid and a PVC helix reinforcement and a PVC cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 2" – 8" (51 – 203 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 50 – 100 PSI. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

The published range for the standard construction is -5°C – +60°C. Confirm continuous operation with the actual fluid, pressure and duty cycle. No separate short-term peak rating is documented for this series; higher-temperature operation requires a separately confirmed specification.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 6, 10, 12, 30 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

What suction or vacuum rating applies?

The model table does not document a vacuum limit. Request a suction rating for the exact size, temperature and duty before selection; positive-pressure values do not establish full-vacuum capability.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Hybrid Air Hose

What construction does this series use?

The construction described on this page has a PVC / synthetic rubber inner tube, polyester yarn reinforcement and a PVC / synthetic rubber cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 1/4" – 3/8" (6 – 9.5 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 20 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

The published range for the standard construction is -40°C – +65°C. Confirm continuous operation with the actual fluid, pressure and duty cycle. No separate short-term peak rating is documented for this series; higher-temperature operation requires a separately confirmed specification.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 7.62, 15.24, 30.48 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Provide the medium, concentration, temperature and operating pressure. Confirm compatibility for the selected compound and fittings. Food-contact, drinking-water or other regulated uses require documents covering the actual model and intended use; they are not included merely because the hose is PVC, rubber or TPU.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

LPG Hose

What construction does this series use?

The construction described on this page has a PVC inner tube, polyester yarn reinforcement and a PVC cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 3/8" – 1/2" (9.2 – 13 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 2 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

The published range for the standard construction is -5°C – +60°C. Confirm continuous operation with the actual fluid, pressure and duty cycle. No separate short-term peak rating is documented for this series; higher-temperature operation requires a separately confirmed specification.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 100 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Specify the gas composition, pressure, installation and destination-market requirements. Confirm the selected hose and complete assembly for that service; an LPG product description does not also establish natural-gas approval or a universal replacement interval.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

PVC Air Hose

What construction does this series use?

The construction described on this page has a PVC inner tube, polyester yarn reinforcement and a PVC cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 1/4" – 2" (6.5 – 50 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 15 – 30 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 40, 50, 100 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Provide the medium, concentration, temperature and operating pressure. Confirm compatibility for the selected compound and fittings. Food-contact, drinking-water or other regulated uses require documents covering the actual model and intended use; they are not included merely because the hose is PVC, rubber or TPU.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

PVC Garden Hose

What construction does this series use?

The construction described on this page has a PVC inner tube, synthetic textile reinforcement and a PVC cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 1/2" – 1" (12 – 25 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 4 – 8 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

The published range for the standard construction is -5°C – +60°C. Confirm continuous operation with the actual fluid, pressure and duty cycle. No separate short-term peak rating is documented for this series; higher-temperature operation requires a separately confirmed specification.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 50, 100 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Provide the medium, concentration, temperature and operating pressure. Confirm compatibility for the selected compound and fittings. Food-contact, drinking-water or other regulated uses require documents covering the actual model and intended use; they are not included merely because the hose is PVC, rubber or TPU.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

PVC High Pressure Spray Hose

What construction does this series use?

The construction described on this page has a PVC inner tube, two layers of polyester yarn reinforcement and a PVC cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 1/4" – 1" (6.5 – 25 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 25 – 40 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

The published range for the standard construction is -5°C – +60°C. Confirm continuous operation with the actual fluid, pressure and duty cycle. No separate short-term peak rating is documented for this series; higher-temperature operation requires a separately confirmed specification.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 50, 100 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Provide the medium, concentration, temperature and operating pressure. Confirm compatibility for the selected compound and fittings. Food-contact, drinking-water or other regulated uses require documents covering the actual model and intended use; they are not included merely because the hose is PVC, rubber or TPU.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

PVC Shower Hose

What construction does this series use?

The construction described on this page has a PVC inner tube, synthetic textile reinforcement and a PVC cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 5/16" – 3/8" (8 – 9.5 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 10 – 15 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

The published range for the standard construction is -5°C – +80°C. Confirm continuous operation with the actual fluid, pressure and duty cycle. No separate short-term peak rating is documented for this series; higher-temperature operation requires a separately confirmed specification.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 50, 100 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Provide the medium, concentration, temperature and operating pressure. Confirm compatibility for the selected compound and fittings. Food-contact, drinking-water or other regulated uses require documents covering the actual model and intended use; they are not included merely because the hose is PVC, rubber or TPU.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

PVC Steel Wire Reinforced Hose

What construction does this series use?

The construction described on this page has a PVC inner tube, a galvanized steel-wire spiral reinforcement and a PVC cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 5/16" – 10" (8 – 254 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 2 – 8 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 10, 20, 30, 40, 50, 100 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

What suction or vacuum rating applies?

The model table does not document a vacuum limit. Request a suction rating for the exact size, temperature and duty before selection; positive-pressure values do not establish full-vacuum capability.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

PVC Suction Hose

What construction does this series use?

The construction described on this page has a PVC inner tube, a rigid PVC helix reinforcement and a PVC cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 3/4" – 8" (19 – 203 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 2.5 – 5 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

The published range for the standard construction is -5°C – +60°C. Confirm continuous operation with the actual fluid, pressure and duty cycle. No separate short-term peak rating is documented for this series; higher-temperature operation requires a separately confirmed specification.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 10, 12, 20, 30, 50 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

What suction or vacuum rating applies?

The model table does not document a vacuum limit. Request a suction rating for the exact size, temperature and duty before selection; positive-pressure values do not establish full-vacuum capability.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

PVC Twin Welding Hose

What construction does this series use?

This series has separate oxygen and acetylene channels. The pressure summary identifies each channel individually; keep the hose markings and end connections matched to the intended gas. Confirm the applicable welding-gas standard and assembly requirements for the destination market.

Which sizes belong to the listed series?

The listed models cover 1/5" – 3/8" (5 – 10 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are O₂: 20 bar / C₂H₂: 10 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

The published range for the standard construction is -10°C – +60°C. Confirm continuous operation with the actual fluid, pressure and duty cycle. No separate short-term peak rating is documented for this series; higher-temperature operation requires a separately confirmed specification.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 30, 50 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Sewer Jetting & Cleaning Hoses

What construction does this series use?

The construction described on this page has a polyamide inner tube, two synthetic-fibre braids reinforcement and a polyurethane cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 3/8" – 1-1/4" (10 – 32.8 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 173 – 280 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

Is this bulk hose or a finished assembly?

The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Provide the medium, concentration, temperature and operating pressure. Confirm compatibility for the selected compound and fittings. Food-contact, drinking-water or other regulated uses require documents covering the actual model and intended use; they are not included merely because the hose is PVC, rubber or TPU.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

TPU Suction Hose With Helix

What construction does this series use?

The construction described on this page has a TPU inner tube, steel wire or a white PVC helix, as specified for the selected version reinforcement and a TPU cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 3/4" – 8" (19 – 200 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 0.35 – 2.75 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 10 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

What suction or vacuum rating applies?

The table lists 0.055 – 0.55 bar. Use the value for the chosen diameter and operating conditions. This is not a blanket full-vacuum rating for every model. P− values are listed as vacuum magnitudes, not positive working pressures.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Layflat Hoses

Heavy Duty Layflat Water Discharge Hose

What construction does this series use?

The construction described on this page has a PVC/NBR inner tube, synthetic textile reinforcement and a PVC cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 3/4" – 8" (20 – 203 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 6 – 10 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 50 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Provide the medium, concentration, temperature and operating pressure. Confirm compatibility for the selected compound and fittings. Food-contact, drinking-water or other regulated uses require documents covering the actual model and intended use; they are not included merely because the hose is PVC, rubber or TPU.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Medium Duty Layflat Discharge Hose

What construction does this series use?

The construction described on this page has a PVC inner tube, synthetic textile reinforcement and a PVC cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 3/4" – 8" (20 – 203 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 5 – 6 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

The published range for the standard construction is -5°C – +60°C. Confirm continuous operation with the actual fluid, pressure and duty cycle. No separate short-term peak rating is documented for this series; higher-temperature operation requires a separately confirmed specification.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 100 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Provide the medium, concentration, temperature and operating pressure. Confirm compatibility for the selected compound and fittings. Food-contact, drinking-water or other regulated uses require documents covering the actual model and intended use; they are not included merely because the hose is PVC, rubber or TPU.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

PVC Layflat Hose

What construction does this series use?

The construction described on this page has a PVC inner tube, synthetic textile reinforcement and a PVC cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 1" – 16" (25 – 408 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 2 – 4 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

The published range for the standard construction is -5°C – +60°C. Confirm continuous operation with the actual fluid, pressure and duty cycle. No separate short-term peak rating is documented for this series; higher-temperature operation requires a separately confirmed specification.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 50, 100 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Provide the medium, concentration, temperature and operating pressure. Confirm compatibility for the selected compound and fittings. Food-contact, drinking-water or other regulated uses require documents covering the actual model and intended use; they are not included merely because the hose is PVC, rubber or TPU.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

TPU Layflat Hose

What construction does this series use?

The construction described on this page has a TPU inner tube, polyester yarn reinforcement and a TPU cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 1" – 14" (25 – 356 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 5 – 42 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 20–200 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How do the TPU pressure grades and compound options differ?

For SHPU0152, the listed WP grades are 16/28/42 bar and the corresponding BP values are 48/84/84 bar, in the same order. Keep each pair together. Confirm the TPU compound for the ordered version; no universal abrasion multiplier or service life is specified.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Rubber Hoses

Double Braided Rubber Multi-Purpose Hose

What construction does this series use?

The construction described on this page has a NR/SBR inner tube, two textile layers reinforcement and a EPDM cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 1/2" – 1-1/2" (13 – 38 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 15 – 20 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 50, 100 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

The documented series is for air and water applications. Steam service is not established by its listed pressure values; request a separately specified and documented steam hose if steam is involved.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Rubber Air Hose

What construction does this series use?

The construction described on this page has a NR/SBR inner tube, synthetic textile reinforcement and a NR/SBR cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 3/16" – 2" (5 – 51 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 15 – 20 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 50, 100 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

The documented series is for air and water applications. Steam service is not established by its listed pressure values; request a separately specified and documented steam hose if steam is involved.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Rubber Fuel & Oil Hose

What construction does this series use?

The construction described on this page has a NBR inner tube, synthetic textile reinforcement and a NBR cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 3/16" – 2" (5 – 51 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 10 – 20 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 50, 100 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Specify the exact fuel, additives and any biodiesel content. Confirm compatibility for the selected NBR compound and fittings; the general fuel/oil description is not a documented approval for every blend.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Rubber Suction & Discharge Hose

What construction does this series use?

The construction described on this page has a NBR inner tube, synthetic cord and helical steel wire reinforcement and a synthetic rubber cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 1-1/2" – 14" (38 – 350 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 10 bar. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

Is this bulk hose or a finished assembly?

The model table lists coil lengths of 10, 12 m. Check the length against the chosen model. The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

What suction or vacuum rating applies?

The table lists -0.85 bar. Use the value for the chosen diameter and operating conditions. This is not a blanket full-vacuum rating for every model.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Hydraulic Hoses

Hydraulic Hose DIN EN 856 4SH

What construction does this series use?

The construction described on this page has a synthetic rubber inner tube, four spiral steel-wire layers reinforcement and a synthetic rubber cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 3/4" – 2" (19 – 51 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 25 – 42 MPa. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

Is this bulk hose or a finished assembly?

The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Provide the medium, concentration, temperature and operating pressure. Confirm compatibility for the selected compound and fittings. Food-contact, drinking-water or other regulated uses require documents covering the actual model and intended use; they are not included merely because the hose is PVC, rubber or TPU.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Hydraulic Hose DIN EN 856 4SP

What construction does this series use?

The construction described on this page has a synthetic rubber inner tube, four spiral steel-wire layers reinforcement and a synthetic rubber cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 1/4" – 2" (6.3 – 51 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 16.5 – 45 MPa. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

Is this bulk hose or a finished assembly?

The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Provide the medium, concentration, temperature and operating pressure. Confirm compatibility for the selected compound and fittings. Food-contact, drinking-water or other regulated uses require documents covering the actual model and intended use; they are not included merely because the hose is PVC, rubber or TPU.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Hydraulic Hose R1AT/1SN

What construction does this series use?

The construction described on this page has a synthetic rubber inner tube, one steel-wire braid reinforcement and a synthetic rubber cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 3/16" – 2" (5 – 51 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 2.6 – 21 MPa. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

Is this bulk hose or a finished assembly?

The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Provide the medium, concentration, temperature and operating pressure. Confirm compatibility for the selected compound and fittings. Food-contact, drinking-water or other regulated uses require documents covering the actual model and intended use; they are not included merely because the hose is PVC, rubber or TPU.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Hydraulic Hose SAE 100 R2AT/2SN

What construction does this series use?

The construction described on this page has a NBR inner tube, two steel-wire braids reinforcement and a synthetic rubber cover. Confirm the compound and construction against the selected model when ordering.

Which sizes belong to the listed series?

The listed models cover 3/16" – 2" (5 – 51 mm). Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

The working pressures listed for this series are 7.8 – 35 MPa. Use the value for the selected model and grade, not the highest value across the series. Working pressure and burst pressure are separate limits; a burst-test value is not an operating pressure. Where BP is listed, use its pairing with WP in the same row; do not assume one burst ratio for every model.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

Is this bulk hose or a finished assembly?

The hose ratings describe the hose itself. Cut lengths, connectors and finished assemblies must be agreed in the quotation, including end fittings and any assembly testing. A coil length does not specify a finished assembly length or rating.

How should suitability for the application be confirmed?

Provide the medium, concentration, temperature and operating pressure. Confirm compatibility for the selected compound and fittings. Food-contact, drinking-water or other regulated uses require documents covering the actual model and intended use; they are not included merely because the hose is PVC, rubber or TPU.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (m). Bulk hose: m; Finished assemblies: pieces — Confirm by model. Send the model, size, material, intended medium, operating conditions and quantity. Specify bulk hose in metres and assemblies or fittings in pieces. Confirm minimum quantity, packaging and lead time in the quotation for the chosen configuration; optional versions may have different order requirements.

Hose Clamps

American Type Hose Clamps

How is this clamp tightened?

This series uses a worm-drive screw to tighten the band around the hose.

Which sizes belong to the listed series?

The listed models cover 11 – 178 mm. Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What tightening torque and material grade apply?

Use the material code and torque specified for the exact model. The available tables do not establish one torque for every size and material; request confirmation where the row is blank or the instructions differ. Confirm the band, housing and screw materials separately.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: 1000 (pieces). Send the clamp model, clamping range, material code and quantity in pieces. Confirm minimum order, packaging and lead time for that configuration in the quotation.

British Type Hose Clamp

How is this clamp tightened?

This series uses a worm-drive screw to tighten the band around the hose.

Which sizes belong to the listed series?

The listed models cover 9.5 – 180 mm. Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification. The documented band width is 9.7 – 11.7 mm; blank cells need model-specific confirmation.

What tightening torque and material grade apply?

Use the material code and torque specified for the exact model. The available tables do not establish one torque for every size and material; request confirmation where the row is blank or the instructions differ. Confirm the band, housing and screw materials separately.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: 1000 (pieces). Send the clamp model, clamping range, material code and quantity in pieces. Confirm minimum order, packaging and lead time for that configuration in the quotation.

Double Bolts and Double Bands Super Hose Clamp

How is this clamp tightened?

This series uses two bolts and two bands. Choose the model and material code together; the table includes different material executions rather than one universal all-stainless version.

Which sizes belong to the listed series?

The listed models cover 35 – 300 mm. Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification. The documented band width is 20 – 24 mm; blank cells need model-specific confirmation.

What tightening torque and material grade apply?

Use the material code and torque specified for the exact model. The available tables do not establish one torque for every size and material; request confirmation where the row is blank or the instructions differ. Confirm the band, housing and screw materials separately.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: 1000 (pieces). Send the clamp model, clamping range, material code and quantity in pieces. Confirm minimum order, packaging and lead time for that configuration in the quotation.

Double Wire Hose Clamps

How is this clamp tightened?

This double-wire clamp is adjusted with a screw. It is not an ear clamp closed by crimping; choose the listed clamping range for the assembled hose connection.

Which sizes belong to the listed series?

The listed models cover 11 – 120 mm. Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What tightening torque and material grade apply?

Use the material code and torque specified for the exact model. The available tables do not establish one torque for every size and material; request confirmation where the row is blank or the instructions differ. Confirm the band, housing and screw materials separately.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: 1000 (pieces). Send the clamp model, clamping range, material code and quantity in pieces. Confirm minimum order, packaging and lead time for that configuration in the quotation.

German Type Hose Clamp

How is this clamp tightened?

This is a worm-drive clamp with a non-perforated band. Select the material code from its material table; stainless content depends on the band, housing and screw, not just the product name.

Which sizes belong to the listed series?

The listed models cover 12 – 190 mm. Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What tightening torque and material grade apply?

Use the material code and torque specified for the exact model. The available tables do not establish one torque for every size and material; request confirmation where the row is blank or the instructions differ. Confirm the band, housing and screw materials separately.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: 1000 (pieces). Send the clamp model, clamping range, material code and quantity in pieces. Confirm minimum order, packaging and lead time for that configuration in the quotation.

Heavy Duty Hose Clamp With Single Bolt

How is this clamp tightened?

This heavy-duty series is tightened with one bolt. Select its listed size and material execution to suit the completed connection.

Which sizes belong to the listed series?

The listed models cover 68 – 260 mm. Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification. The documented band width is 30 mm; blank cells need model-specific confirmation.

What tightening torque and material grade apply?

Use the material code and torque specified for the exact model. The available tables do not establish one torque for every size and material; request confirmation where the row is blank or the instructions differ. Confirm the band, housing and screw materials separately.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: 1000 (pieces). Send the clamp model, clamping range, material code and quantity in pieces. Confirm minimum order, packaging and lead time for that configuration in the quotation.

Camlock Couplings

Camlock Couplings

How do I choose the camlock connection type?

A is a male adapter with a female thread; B is a female coupler with a male thread. C and E have hose shanks; D is a female coupler with a female thread, and F is a male adapter with a male thread. DC and DP are dust closures. Check the required type, size, thread and mating dimensions; do not assume a dust closure has a pressure rating.

Which sizes belong to the listed series?

Sizes differ by material and connection type. Ask for the drawing and size list for the selected combination; this mixed-material overview does not define one standard range for every version.

What working pressure should I use?

A confirmed pressure rating is required for the exact material, size, connection type, seal and service temperature. Dimensional tables alone do not establish it. Request a model-specific rating before selection; no single maximum applies to every coupling or closure on this page.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

How are the seal and hose assembly specified?

State the fluid, concentration, temperature, hose dimensions and retention method. Agree the seal compound, thread and complete assembly in the quotation. A separately supplied coupling is not a tested hose assembly; other seal materials or combinations need confirmation.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (pieces). Send the coupling type, size, material, seal, thread and quantity in pieces. Confirm the minimum order, packaging and lead time for the selected model in the quotation.

Polypropylene Camlock Coupling

How do I choose the camlock connection type?

A is a male adapter with a female thread; B is a female coupler with a male thread. C and E have hose shanks; D is a female coupler with a female thread, and F is a male adapter with a male thread. DC and DP are dust closures. Check the required type, size, thread and mating dimensions; do not assume a dust closure has a pressure rating. The PP series described here is not for compressed air or gases. PP dust caps and plugs are not for pressure service.

Which sizes belong to the listed series?

The listed models cover 1/2" – 4". Select an actual row in the specification table; the range does not mean every intermediate size is stocked. Sizes outside the table require a separate quotation and specification.

What working pressure should I use?

A confirmed pressure rating is required for the exact material, size, connection type, seal and service temperature. Dimensional tables alone do not establish it. Request a model-specific rating before selection; no single maximum applies to every coupling or closure on this page.

What is the temperature range, including short-term peaks?

A single confirmed temperature range is not yet available for this series. Ask for the continuous-service limit for the selected model, fluid and pressure before ordering. Any short-term peak must be specified separately with its permitted duration and conditions; no peak allowance is included by default.

How are the seal and hose assembly specified?

State the fluid, concentration, temperature, hose dimensions and retention method. Agree the seal compound, thread and complete assembly in the quotation. A separately supplied coupling is not a tested hose assembly; other seal materials or combinations need confirmation.

Are other materials, sizes or certified versions standard?

The listed model and material define the standard specification shown here. Treat requests for other compounds, colors, reinforcement, sizes or compliance documents as separate options, subject to written confirmation. A generic material name or standard reference is not a certificate for every model.

What information is needed for a quotation and minimum order?

MOQ: Confirm by model (pieces). Send the coupling type, size, material, seal, thread and quantity in pieces. Confirm the minimum order, packaging and lead time for the selected model in the quotation.

Question Not Answered?

Our engineers reply within 8 hours with technical specs, samples or a quotation.

💬
Get a Quote WhatsApp